
Rain Master Irrigation Systems DX2 User Manual
Chapter 10: Troubleshooting Page 205
029 - Auto Limits Aborted
Figure 170: Warning 029 -Auto Limits
The automatic calculation of the Auto Limits feature had to be
stopped due to a potentially hazardous over current situation at
this satellite. This warning only occurs when the Auto Limits
feature is running. This alarm may be preceded by a SHORT
CIRCUIT alarm, indicating the station with the short circuit
condition.
Action:
Step 1 Correct the short circuit (over current) condition at
the station. The problem station may be identified
by performing the Multi-Station Diagnostics
procedure.
Step 2 CLEAR all alarms.
Step 3 Re-run the AUTO LIMITS function.
Step 4 IMPORTANT:
Upon resolution of problem, CLEAR all warnings at
the satellites.
WARNING = AUTO LIM ABORT 06/21/96 02:48PM
|¾||½|
Komentáře k této Příručce