Rain Master Irrigation Systems DX2 User Manual
Chapter 10: Troubleshooting Page 181
010 - Hardwire Communication Failure
Figure 151: Warning 010-Hardwire Communication Failure
A submaster has lost hardwire communications comm. with one
or more satellites. Hardwire communications occur between the
submaster and its satellites at the rate of once every 0.1 seconds.
Loss of communications may be temporary (power glitch) or
permanent (severed EV-CAB-COM communications cable). In
either case, irrigation will continue at the satellites without
interruption as long as the configuration does not utilize the Flow
Max feature. This message will be accompanied by a
corresponding message at one or more satellites, "OFFLINE."
Action:
Step 1 Hardwire communications failures may be caused by
any of the following: power failures, improper
hardwire connections at the communications board,
or broken/severed communications cable.
Step 2 Starting with the first satellite which is connected to
the submaster examine the satellite address to verify
address XX-01 appears in the LCD display. If there
is no address and the controller is on, then a problem
related to the communications cable or its
connections has occurred somewhere between the
submaster and this unit. If the address is OK,
examine the satellite warning list for any related
warning messages, e.g. momentary power failure. If
address is OK and there are no related warnings,
proceed to the next satellite and troubleshoot as
above. Because the communications cable is wired
WARNING = HW COMM FAIL 03/20/93 04:30PM
|¾||½|