Page 262 Appendix B: Current Monitor
Example Current Limit Violations
Station Consumes Too Much Current
Assume the maximum station current for station 7 is set to .60
Amps. While watering on Station 7 (no Pump, Master Valve or
other stations on) is in progress, .85 Amps of current are
detected. Watering is stopped on Station 7. The base menu will
now display F2=WARNING and an entry is made in the warning
list.
See "Maximum Controller Current" section for additional
details.
Figure 192: Warning, Up Limit
Station Consumes Too Little Current
Assume the minimum limit is set to 0.15 Amps. While watering
on Station 2 is in progress, 0.00 Amps is detected. Watering on
Station 2 is stopped. The base menu will now display
F2=WARNING and an entry is made in the warning list.
Figure 193: Warning, Low Limit
Multiple Stations with Non-Overlap Protection
The Evolution DX2 controller allows several stations to be on
simultaneously. When current limit checking is used in this
WARNING = I UP LIMIT 05/21/96 11:56
STA = 7 I=.85 AMPS |½|
WARNING = I LOW LIMIT 08/21/95 12:06
STA = 2 I=.00 AMPS |½|